Skip to content

HEMSystemLivePower

Live power data for a HEM system, including raw measurements and derived power flows.

sampled_atstring, (date-time)read-onlyrequired

The timestamp of the energy statistics period.

Example:"2024-06-15T12:00:00Z"
generation_wattsinteger or nullread-onlyrequired

Solar generation power in watts. Null if inverter stats unavailable.

Example:3000
consumption_wattsinteger or nullread-onlyrequired

Household consumption power in watts. Null if any required stats unavailable.

Example:2400
import_wattsinteger or nullread-onlyrequired

Power imported from the grid in watts. Null if any required stats unavailable.

Example:1200
export_wattsinteger or nullread-onlyrequired

Power exported to the grid in watts. Null if any required stats unavailable.

Example:600
charge_wattsinteger or nullread-onlyrequired

Battery charging power in watts. Null if any required stats unavailable.

Example:1800
discharge_wattsinteger or nullread-onlyrequired

Battery discharging power in watts. Null if any required stats unavailable.

Example:900
solar_to_home_wattsinteger or nullread-onlyrequired

Derived power flow from solar to home in watts. Null if any required stats unavailable.

Example:1500
solar_to_battery_wattsinteger or nullread-onlyrequired

Derived power flow from solar to battery in watts. Null if any required stats unavailable.

Example:1000
solar_to_grid_wattsinteger or nullread-onlyrequired

Derived power flow from solar to grid in watts. Null if any required stats unavailable.

Example:500
battery_to_home_wattsinteger or nullread-onlyrequired

Derived power flow from battery to home in watts. Null if any required stats unavailable.

Example:700
battery_to_grid_wattsinteger or nullread-onlyrequired

Derived power flow from battery to grid in watts. Null if any required stats unavailable.

Example:200
grid_to_home_wattsinteger or nullread-onlyrequired

Derived power flow from grid to home in watts. Null if any required stats unavailable.

Example:200
grid_to_battery_wattsinteger or nullread-onlyrequired

Derived power flow from grid to battery in watts. Null if any required stats unavailable.

Example:100
battery_state_of_charge_percentageinteger or nullread-onlyrequired

Battery state of charge as a percentage (0-100). Null if unavailable.

Example:82
{ "sampled_at": "2024-06-15T12:00:00Z", "generation_watts": 3000, "consumption_watts": 2400, "import_watts": 1200, "export_watts": 600, "charge_watts": 1800, "discharge_watts": 900, "solar_to_home_watts": 1500, "solar_to_battery_watts": 1000, "solar_to_grid_watts": 500, "battery_to_home_watts": 700, "battery_to_grid_watts": 200, "grid_to_home_watts": 200, "grid_to_battery_watts": 100, "battery_state_of_charge_percentage": 82 }